When increasing the setting value of P2-44 and P2-46 manually, ensure to pay close attention on
the setting value of P2-44 and P2-46. If the value of P2-44 and P2-46 is greater than 0, it indicates
that the corresponding resonance frequency of P2-43 and P2-45 is found through auto resonance
suppression function. If the value of P2-44 and P2-46 is equal to 0, it indicates that the value of P2-
43 and P2-45 will be the default value 1000 and this is not the frequency found by auto resonance
suppression function. At this time, if the users increase the value of notch filter attenuation rate
which does not exist, the performance of the current mechanical system may deteriorate.
Current Value
0
0
1
1
1
2
2
2
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Settings of P2-47
Desired Value
Clear the setting value of P2-43 ~ P2-46 and enable
1
auto resonance suppression function.
Clear the setting value of P2-43 ~ P2-46 and enable
2
auto resonance suppression function.
Save the setting value of P2-43 ~ P2-46 and disable
0
auto resonance suppression function.
Clear the setting value of P2-43 ~ P2-46 and enable
1
auto resonance suppression function.
Do not clear the setting value of P2-43 ~ P2-46 and
2
enable auto resonance suppression function
continuously.
Save the setting value of P2-43 ~ P2-46 and disable
0
auto resonance suppression function.
Clear the setting value of P2-43 ~ P2-46 and enable
1
auto resonance suppression function.
Do not clear the setting value of P2-43 ~ P2-46 and
2
enable auto resonance suppression function
continuously.