Timing Chart Of Speed Control Mode; Speed Loop Gain Adjustment - Delta Electronics ASDA-B2 series User Manual

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

Chapter 6 Control Modes of Operation

6.3.5 Timing Chart of Speed Control Mode

Internal speed
command
External analog
voltage or zero (0)
External I/O signal
NOTE
1) OFF indicates normally open and ON indicates normally closed.
2) When speed control mode is Sz, the speed command S1=0; when speed control mode is
S, the speed command S1 is external analog voltage input (Please refer to P1-01).
3) After Servo ON, the users can select command according to the state of SPD0~1.

6.3.6 Speed Loop Gain Adjustment

The function and structure of speed control mode is shown as the figure below:
6-20
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
S4 (P1-11)
S3 (P1-10)
S2 (P1-09)
S1
SPD0
SPD1
SON
OFF
ON
OFF
ON
ASDA-B2
OFF
ON
ON
Revision September 2013

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents