Chapter 9 Troubleshooting
Display
Fault Name
Encoder output error
Serial communication
error
Serial communication
time out
Reserved
Input power phase loss One phase of the input power is loss.
Pre-overload warning
Encoder initial
magnetic field error
Encoder internal error
Encoder data error
Motor internal error
Motor internal error
Motor internal error
Motor protection error
U,V,W, GND wiring
error
Motor temperature
error
Excessive encoder
output error
Motor temperature
warning
DSP firmware upgrade
NOTE
1) If there is any unknown fault code that is not listed on the above table, please inform the
distributor or contact with Delta for assistance.
9-2
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Fault Messages
The encoder output exceeds the rated output frequency.
RS232/485 communication is in error.
RS232/485 communication time out.
Reserve
To warn that the servo motor and drive is going to overload.
This alarm will display before ALM06. When the servo motor
reach the setting value of P1-56, the motor will send a
warning to the drive. After the drive has detected the warning,
the DO signal OLW will be activated and this fault message
will display.
The magnetic field of the encoder U, V, W signal is in error.
The internal memory of the encoder is in error. An internal
counter error is detected.
An encoder data error is detected for three times.
The setting value of the encoder is in error.
The encoder U, V, W signals are in error.
The internal address of the encoder is in error.
In order to protect the motor, this alarm will be activated
when the setting value of P1-57 is reached after a period of
time set by P1-58.
The wiring connections of U, V, W (for servo motor output)
and GND (for grounding) are in error.
Motor is working under temperature over 105°C (221°F).
The encoder output errors or output pulses exceed hardware
tolerance.
The temperature of motor is over 85°C (185°F).
EE-PROM is not reset after the firmware version is upgraded.
This fault can be cleared after setting P2-08 to 30 first, and
then setting P2-08 to 28 next and restarting the ervo drive.
Fault Description
Revision September 2013