Chapter 7 Servo Parameters
Settings:
In speed mode, the users can use this parameter to add an offset value to analog
speed input.
P4-23
TAO
Operation
Interface:
Default: 0
Control
Mode:
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Display
Format:
Settings:
In speed mode, the users can use this parameter to add an offset value to analog
speed input.
P4-24
LVL
Operation
Interface:
Default: 160
Control
Mode:
Unit: V (rms)
Range: 140 ~ 190
Data Size: 16-bit
Display
Format:
Settings:
When DC Bus voltage is lower than the value of P4-24 x
will occur.
7-92
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Analog Torque Input Offset
Keypad / Software
T
Decimal
Undervoltage Error Level
Keypad / Software
ALL
Decimal
Communication
Communication
, the fault, Undervoltage
2
ASDA-B2
Address: 042EH
042FH
Related Section: N/A
Address: 0430H
0431H
Related Section: N/A
Revision September 2013