Chapter 7 Servo Parameters
P4-07■
ITST
Operation
Interface:
Default: 0
Control
Mode:
Unit: N/A
Range: 0 ~ 01FF
Data Size: 16-bit
Display
Format:
Settings:
The control of digital inputs can be determined by the external terminals (DI1 ~ DI9) or
by the internal software digital inputs SDI1 ~ SDI9 (corresponds to Bit0 ~ Bit8 of P1-47)
via communication (upon software). Please refer to P3-06 and section 8.2 for the
setting method.
External DIs
Internal DIs
Read P4-07: Display the final status of DI input signal.
Write P4-07: Write the status of software digital inputs SDI1 ~ SDI9
(No matter the servo drive is controller through digital keypad or communication
control, the function of this parameter is the same.)
For example:
External Control: Display the final status of DI input signal
When the read value of P4-07 is 0x0011, it indicates that DI1 and DI5 are ON.
Communication Control (Internal DIs): Read the status of input signal (upon software).
For example:
When the write value of P4-07 is 0x0011, it indicates that software digital inputs SDI1
and SDI5 are ON.
Bit0 ~ Bit8 corresponds with DI1 ~ DI9.
For the settings of DI1 ~ DI9, please refer to P2-10 ~ P2-17 and P2-36.
P4-08★
PKEY Digital Keypad Input of Servo Drive
Operation
Interface:
Default: N/A
Control
Mode:
7-86
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
the force output function.)
Input Status
Software (cannot read
and write throught the
panel)
ALL
Hexadecimal
P3-06
Keypad / Software
ALL
Communication
Read or Write
Final DI Status
Communication
ASDA-B2
Address: 040CH
040DH
Related Section:
Section 4.4.4
Section 8.2
Address: 0410H
0411H
Related Section: N/A
Revision September 2013