Delta Electronics ASDA-B2 series User Manual page 296

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
Motor temperature error
:
Potential Cause
Motor is working under
temperature over 105°C
(221°F).
Excessive encoder output error
:
Potential Cause
Encoder error causes
abnormal encoder
output.
Output pulses exceed
hardware tolerance.
Motor temperature warning
:
Potential Cause
Motor is working under
temperature over 85°C
(185°F).
DSP firmware upgrade
:
Potential Cause
EE-PROM is not reset
after the firmware
version is upgraded.
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Checking Method
Check if the environment temperature is
too high.
Checking Method
Exam error records (P4-00~P4-05)
to check if encoder errors
occurred. (AL011, AL024, AL025,
AL026)
Check if conditions below occur,
P1-76 < Motor rotation speed, or,
Motor
rotation
speed
 P
1
46
60
Checking Method
Check if the environment temperature is
too high.
Checking Method
Check if EE-PROM is reset after the
firmware version is upgraded.
Try to reduce environment
temperature.
Corrective Actions
Please refer to AL011, AL024, AL025,
AL026 and take corrective actions.
Correctly set P1-76 and P1-46:
P1-76 > Motor rotation speed, and,
Motor
rotation
4
19.8
10
60
Try to reduce environment
temperature.
Set P2-08 to 30 first, and then
28 next, and restart the servo
drive.
Chapter 9 Troubleshooting
Corrective Actions
speed
 P
1
46
4
19.8
10
Corrective Actions
Corrective Actions
9-11
6

Hide quick links:

Advertisement

Table of Contents
loading