P2-44
DPH2
Operation
Interface:
Default: 0
Control
Mode:
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set magnitude of the resonance suppression that is set by
parameter P2-43. If P2-44 is set to 0, the parameters P2-43 and P2-44 are both
disabled.
P2-45
NCF3
Operation
Interface:
Default: 1000
Control
Mode:
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set third resonance frequency of mechanical system. It can
be used to suppress the resonance of mechanical system and reduce the vibration of
mechanical system.
If P2-45 is set to 0, this parameter is disabled.
P2-46
DPH3
Operation
Interface:
Default: 0
Control
Mode:
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
7-66
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Notch Filter Attenuation Rate 2
(Resonance Suppression)
Keypad/Software
ALL
Decimal
Notch Filter 3 (Resonance Suppression)
Keypad/Software
ALL
Decimal
Notch Filter Attenuation Rate 3
(Resonance Suppression)
Keypad/Software
ALL
Decimal
Communication
Communication
Communication
ASDA-B2
Address: 0258H
0259H
Related Section:
Section 6.3.7
Address: 025AH
025BH
Related Section:
Section 6.3.7
Address: 025CH
025DH
Related Section:
Section 6.3.7