Delta Electronics ASDA-B2 series User Manual page 194

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
P1-08
PFLT
Operation
Interface:
Default: 0
Control
Mode:
Unit: 10ms
Range: 0 ~ 1000
Data Size: 16-bit
Display
Format:
Settings: 0: Disabled
For example: 11=110 msec
P1-09
SP1
Operation
Interface:
Default: 1000
Control
Mode:
Unit: 0.1r/min
Range: -50000 ~ +50000
Data Size: 32-bit
Display
Format:
Settings:
For example: 120=12 r/min
1st Speed Command
In Speed mode, this parameter is used to set speed 1 of internal speed command.
1st Speed Limit
In Torque mode, this parameter is used to set speed limit 1 of internal speed
command.
P1-10
SP2
Operation
Interface:
Default: 2000
Control
Mode:
Unit: 0.1r/min
Range: -50000 ~ +50000
Data Size: 32-bit
Display
Format:
Settings:
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Smooth Constant of Position Command
(Low-pass Filter)
Keypad/Software
PT
Decimal
1st Speed Command or Limit
Keypad/Software
S, T
Decimal
2nd Speed Command or Limit
Keypad/Software
S, T
Decimal
Communication
Communication
Communication
Chapter 7 Servo Parameters
Address: 0110H
0111H
Related Section:
Section 6.2.4
Address: 0112H
0113H
Related Section:
Section 6.3.1
Address: 0114H
0115H
Related Section:
Section 6.3.1
7-29