Settings:
This parameter is used to set magnitude of the resonance suppression that is set by
parameter P2-45. If P2-46 is set to 0, the parameters P2-45 and P2-46 are both
disabled.
P2-47
ANCF Auto Resonance Suppression Mode Selection
Operation
Interface:
Default: 1
Control
Mode:
Unit: N/A
Range: 0 ~ 2
Data Size: 16-bit
Display
Format:
Settings:
0: Disable Auto Resonance Suppression Mode.
The setting value of P2-23~P2-24 and P2-43~P2-46 will be fixed and will not be
changed.
1: Auto Resonance Suppression Mode 1 [Non-continuous adjustment]
After the resonance is suppressed, the setting value of P2-23, P2-24, P2-43, P2-44,
P2-45 and P2-46 will be fixed and will not be changed.
2: Auto Resonance Suppression Mode 2 [Continuous adjustment]
The servo drive will perform the resonance suppression continuously (will not stop).
The setting value of P2-23, P2-24, P2-43, P2-44, P2-45 and P2-46 will not be
fixed.
When P2-47 is set to 1, the resonance suppression will be enabled automatically.
After the mechanical system becomes stable, the setting value of P2-47 will return to
0. When the mechanical system is stable, the resonance suppression point will be
memorized. When the mechanical system is not stable, if the servo drive is restarted
or P2-47 is set to 1, the servo drive will estimate the resonance suppression point
again.
When P2-47 is set to 2, the servo drive will perform the resonance suppression
continuously. When the mechanical system becomes stable, the resonance
suppression point will be memorized. When the mechanical system is not stable, if the
servo drive is restarted, the servo drive will estimate the resonance suppression point
again.
When switching the mode#1 or #2 to #0, the setting values of P2-43, P2-44, P2-45
and P2-46 will be saved automatically.
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Keypad/Software
ALL
Decimal
Chapter 7 Servo Parameters
Communication
Address: 025EH
025FH
Related Section: N/A
7-67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents