Delta Electronics ASDA-B2 series User Manual page 236

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
P2-60
GR4
Operation
Interface:
Default: 16
Control
Mode:
Unit: pulse
Range: 1 ~ (2
Data Size: 32-bit
Display
Format:
Settings:
The electronic gear numerator value can be set via GNUM0, GNUM1 (refer to Table
7.A).
When the GNUM0, GNUM1 are not defined, the default of gear numerator value is set
by P1-44.
When the users wish to set the gear numerator value by using GNUM0, GNUM1,
please set P2-60 ~ P2-62 after the servo motor has been stopped to prevent the
mechanical system vibration.
P2-61
GR5
Operation
Interface:
Default: 16
Control
Mode:
Unit: pulse
Range: 1 ~ (2
Data Size: 32-bit
Display
Format:
Settings:
Refer to P2-60 for explanation.
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Electronic Gear Ratio (2nd Numerator) (N2)
Keypad/Software
PT
26
-1)
Decimal
Electronic Gear Ratio (3rd Numerator) (N3)
Keypad/Software
PT
26
-1)
Decimal
Chapter 7 Servo Parameters
Communication
Communication
Address: 0278H
0279H
Related Section: N/A
Address: 027AH
027BH
Related Section: N/A
7-71