Chapter 7 Servo Parameters
For example: 120=12 r/min
2nd Speed Command
In Speed mode, this parameter is used to set speed 2 of internal speed command.
2nd Speed Limit
In Torque mode, this parameter is used to set speed limit 2 of internal speed
command.
P1-11
SP3
Operation
Interface:
Default: 3000
Control
Mode:
Unit: 0.1r/min
Range: -50000 ~ +50000
Data Size: 32-bit
Display
Format:
Settings:
For example: 120=12 r/min
3rd Speed Command
In Speed mode, this parameter is used to set speed 3 of internal speed command.
3rd Speed Limit
In Torque mode, this parameter is used to set speed limit 3 of internal speed
command.
P1-12
TQ1
Operation
Interface:
Default: 100
Control
Mode:
Unit: %
Range: -300 ~ +300
Data Size: 16-bit
Display
Format:
Settings:
1st Torque Command
In Torque mode, this parameter is used to set torque 1 of internal torque command.
1st Torque Limit
In Position and Speed mode, this parameter is used to set torque limit 1 of internal
torque command.
7-30
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
3rd Speed Command or Limit
Keypad/Software
S, T
Decimal
1st Torque Command or Limit
Keypad/Software
T, P&S
Decimal
Communication
Communication
ASDA-B2
Address: 0116H
0117H
Related Section:
Section 6.3.1
Address: 0118H
0119H
Related Section:
Section 6.4.1