Delta Electronics ASDA-B2 series User Manual page 213

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

Chapter 7 Servo Parameters
P1-76
AMSPD Max. Rotation Speed of Encoder Output
Operation
Interface:
Default: 5500
Control
Mode:
Unit: r/min
Range: 0 ~ 6000 (0: Disabled)
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to optimize the encoder outputs (OA, OB). When the users set
the actual reached maximum motor speed, the servo drive will equalize the encoder
outputs automatically. When P1-76 is set to 0, it indicates that equalizing function is
not available.
P1-77
PFLT3 Position Command Moving Filter 2
Operation
Interface:
Default: 4
Control
Mode:
Unit: ms
Range: 0 ~ 100 (0: Disabled)
Data Size: 16-bit
Display
Format:
Settings:
Moving Filter can be used to smooth the start and the end of step position command.
Using Moving Filter can facilitate the smooth operation of the motor very effectively,
but it will cause command delay.
7-48
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Keypad/Software
ALL
Decimal
Keypad/Software
PT
Decimal
Communication
Communication
ASDA-B2
Address: 0198H
0199H
Related Section: P1-46
Address: 019AH
019BH
Related Section: N/A
Revision September 2013