Chapter 6 Control Modes of Operation
actual condition.
Analog Speed Command Low-pass Filter
Analog Speed Command Low-pass Filter is used to eliminate high frequency response
and electrical interference from an analog speed command and it is also with
smoothing function.
Relevant parameters:
P1-06
SFLT
Operation
Interface:
Default: 0
Control
Mode:
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display
Format:
Settings: 0: Disabled
NOTE
1) If the setting value of parameter P1-06 is set to 0, it indicates the function of this
parameter is disabled and the command is just By-Pass.
6-18
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Accel / Decel Smooth Constant of Analog
Speed Command (Low-pass Filter)
Keypad/Software
S
Decimal
Target Speed
Communication
SFLT
ASDA-B2
Address: 010CH
010DH
Related Section:
Section 6.3.3