Delta Electronics ASDA-B2 series User Manual page 176

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
007: Overspeed
008: Abnormal pulse control command
009: Excessive deviation
010: Reserved
011: Encoder error (The wiring of the encoder is in error and this causes the
communication error between the servo drive and the encoder.)
012: Adjustment error
013: Emergency stop activated
014: Reverse limit switch error
015: Forward limit switch error
016: IGBT temperature error
017: Memory error
018: Encoder output error
019: Serial communication error
020: Serial communication time out
021: Reserved
022: Input power phase loss
023: Pre-overload warning
024: Encoder initial magnetic field error
025: Encoder internal error
026: Encoder data error
027: Motor internal error
028: Motor internal error
029: Motor internal error
030: Motor protection error
030: Motor protection error
031: U,V,W, GND wiring error
035: Motor temperature error
048: Excessive encoder output error
067: Motor temperature warning
099: DSP firmware upgrade
P0-02
STS
Operation
Interface:
Default: 00
Control
Mode:
Unit: -
Range: 0 ~ 18
Data Size: 16-bit
Display
Format:
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Drive Status (Front Panel Display)
Keypad/Software
ALL
Decimal
Chapter 7 Servo Parameters
Communication
Address: 0004H
0005H
Related Section:
Section 7.2
7-11

Hide quick links: