Chapter 7 Servo Parameters
P3-03
FLT
Operation
Interface:
Default: 0
Control
Mode:
Unit: N/A
Range: 0 ~ 1
Data Size: 16-bit
Display
Format:
Settings:
0: Display fault and continue operating
1: Display fault and decelerate to stop operating
This parameter is used to determine the operating sequence once a communication
fault has been detected. If '1' is selected, the drive will stop operating upon detection
the communication fault. The mode of stopping is set by parameter P1-32.
P3-04
CWD
Operation
Interface:
Default: 0
Control
Mode:
Unit: sec
Range: 0 ~ 20
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set the maximum permissible time before detecting a fault
due to communication time out. When P3-04 is set to a value over than 0, it indicates
this parameter is enabled. However, if not communicating with the servo in this period
of time, the servo drive will assume the communication has failed and show the
communication error fault message.
When P3-04 is set to 0, this parameter is disabled.
P3-05
CMM
Operation
Interface:
Default: 0
Control
Mode:
Unit: N/A
Range: 0x00 ~ 0x01
Data Size: 16-bit
7-80
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Transmission Fault Treatment
Keypad / Software
ALL
Hexadecimal
Communication Time Out Detection
Keypad / Software
ALL
Decimal
Communication Selection
Keypad / Software
ALL
Communication
Communication
Communication
ASDA-B2
Address: 0306H
0307H
Related Section:
Section 8.2
Address: 0308H
0309H
Related Section:
Section 8.2
Address: 030AH
030BH
Related Section:
Section 8.2
Revision September 2013