Delta Electronics ASDA-B2 series User Manual page 228

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
show 0 and the servo drive will start to adjust the load inertia value continuously.
P2-33▲
AUT3
Operation
Interface:
Default: 0
Control
Mode:
Unit: N/A
Range: 0 ~ 1
Data Size: 16-bit
Display
Format:
Settings:
When the setting value of A is set to 0 or display is 0, it indicates that the load inertia
estimation of semi-auto tuning mode has been executed but not been completed yet.
When the setting value of A is set to 1, it indicates that the load inertia estimation of
semi-auto tuning mode has been completed. The measured load inertia is memorized
in P1-37. If P2-33 is reset to 0, the servo drive will perform continuous adjustment for
estimating the load inertia (P1-37) again.
B: Reserved.
P2-34
SDEV Overspeed Warning Condition
Operation
Interface:
Default: 5000
Control
Mode:
Unit: r/min
Range: 1 ~ 6000
Data Size: 16-bit
Display
Format:
Display Format: Decimal
Settings:
This parameter is used to set the over speed threshold that is used to determine the
over speed fault condition. When the difference in speed between the desired speed
and actual motor speed is over than the setting value of parameter P2-34, the servo
fault, Overspeed (AL007) will be activated.
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Semi-Auto Mode Inertia Adjustment Selection
Keypad/Software
ALL
Decimal
Keypad/Software
S
Decimal
Chapter 7 Servo Parameters
Communication
Communication
Address: 0242H
0243H
Related Section: N/A
Address: 0244H
0245H
Related Section: N/A
7-63