P0-03
MON
Operation
Interface:
Default: 00
Control
Mode:
Unit: -
Range: 00 ~ 77
Data Size: 16-bit
Display
Format:
Settings:
This parameter determines the functions of the analog monitor outputs.
MON1, MON2 Settings:
0: Motor speed (+/-8V / maximum motor speed)
1: Motor torque (+/-8V / maximum torque)
2: Pulse command frequency (+8Volts / 4.5Mpps)
3: Speed command (+/-8Volts / maximum speed command)
4: Torque command (+/-8Volts / maximum torque command)
5: V_BUS voltage (+/-8Volts / 450V)
6: Reserved
7: Reserved
Continuous communication error
Continuous communication error
Continuous communication error
Continuous communication error
P0-03 = 01 (MON1 is motor speed analog output, MON2 is motor torque analog
output)
MON1 output voltage= 8 ×
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Analog Monitor Output
Keypad/Software
ALL
Hexadecimal
Communication error
7-9 times
5-6 times
3-4 times
under 2 times
Communication
Communication quality
3(servere)
2 (bad)
1(moderate)
0 (good)
Motor speed
(Max. motor speed ×
Chapter 7 Servo Parameters
Address: 0006H
0007H
Related Section:
Section 6.6.3
Please note:
For the setting
of analog
output voltage
proportion,
refer to the
P1-04 and
P1-05.
Example:
(unit: Volts)
P1-04
)
100