Delta Electronics ASDA-B2 series User Manual page 184

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
P0-22
Reserved (Do Not Use)
P0-23
Reserved (Do Not Use)
P0-24
Reserved (Do Not Use)
P0-44★
PCMN Status Monitor Register (PC Software Setting)
Operation
Interface:
Default: 0x0
Control
Mode:
Unit: -
Range: determined by the communication address of
Data Size: 32-bit
Display
Format:
Settings:
The function of this parameter is the same as P0-09 (Please refer to P0-09). Please
note that this pamameter can be set through communication setting only.
P0-45■
PCMNA
Operation
Interface:
Default: 0x0
Control
Mode:
Unit: -
Range: 0~127
Data Size: 16-bit
Display
Format:
Settings:
The function of this parameter is the same as P0-17 (Please refer to P0-17). Please
note that this pamameter can be set through communication setting only.
P0-46★
SVSTS Servo Output Status Display
Operation
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0x00 ~ 0xFF
Data Size: 16-bit
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Keypad/Software
ALL
the designated parameter
Decimal
Status Monitor Register Selection (PC
Software Setting)
Keypad/Software
ALL
Decimal
Keypad/Software
ALL
Chapter 7 Servo Parameters
Address: 002CH
Address: 002EH
Address: 0030H
Communication
Communication
Communication
002DH
002FH
0031H
Address: 0058H
0059H
Related Section:
Section 4.3.5
Address: 005AH
005BH
Related Section:
Section 4.3.5
Address: 005CH
005DH
Related Section: N/A
7-19