22. Appendices
22.8.4 Function Calls
ParamLoopBack
Test Function. Entered values are Looped Back.
Arguments
Boolean Par.
Integer Par.
Real Par.
String Par.
Results
Boolean Res.
Integer Res.
Real Res.
String Res.
RampMotorFader
Move a Motor Fader within an entered time
to a defined gain.
Arguments
Source Name
Gain[dB]
Time[s]
Results
Result
0 Success
1 Incorrect number of parameters
2 Incorrect datatype
3 Input value out of range
4 Source / Sum not found
Source / Sum not assigned
5
Combination of values not allowed
6
(level difference to small / time to large)
SetPFLState
Set a Sources PFL State.
Arguments
Source Name
Status
Results
Result
0 Success
1 Incorrect number of parameters
2 Incorrect datatype
4 Source / Sum not found
5 Source / Sum not assigned
POWER CORE User Manual
Type
allowed
B
0 / 1
I
Int
R
Real
U
String
B
I
R
U
Type
allowed
U
existing Sources /
Sums
R
-999 to +9
bounded to -191 to +9
R
0 to 10 ( <0.5 = at once)
I
Type
allowed
U
existing Sources /
Sums
B
0 / 1
I
Version: V6.0.0/5