LAWO POWER CORE User Manual page 155

Hide thumbs Also See for POWER CORE:
Table of Contents

Advertisement

11. Routing Matrix
11.2.6 Logic -> RAVENNA Stream Control
This element can be used to configure redundancy for specific RAVENNA inputs.
Primary and backup streams are specified such that if the primary stream is lost or becomes unknown, then the
backup stream will be connected.
For example, if the Main Stream Name (MSTR:Stream01) is lost, then within 30 seconds the Backup Stream
Name (BKUP:Stream02) will be subscribed. In addition, you can use the Auto Connect control signal to ensure
that the Main Stream (or Backup Stream) is always subscribed.
RAVENNA Stream Control
Input (RAV Core Out)
Main Stream Name
Backup Stream Name
Stream Connect Timeout in
seconds
Alarm Logging Enabled
Auto Connect
Force Main Stream
Connect
Force Backup Stream
Connect
POWER CORE User Manual
Reference name for the element.
Enter the input that will be used to subscribe to the streams from the network.
Enter the name of the Primary or Main stream exactly as it appears in the network.
Enter the name of the Backup or Alternate stream exactly as it appears in the network.
Enter a value from 1 to 300.
Enable whether these connections shall be logged via the Alarm Log Server.
Use this input to ensure that no other undefined streams may be subscribed to this Input.
Any attempt to subscribe to a different stream will cause the Main Stream to be
subscribed instead.
Forces the Main stream to be connected.
Forces the Backup stream to be connected.
Version: V6.0.0/5