LAWO POWER CORE User Manual page 335

Hide thumbs Also See for POWER CORE:
Table of Contents

Advertisement

18. Configuring Custom Logical Behaviour
Trouble-shooting
To verify if all functions of all macro elements have been successfully assigned, the system offers a Telnet shell
command. Once the session is open:
1.
Type macro and press Enter for an overview of Macros 1 to 32 - for example:
pty0 [/] # macro
macro
macro definitions for macro 1 to macro 32
dumping macro definitions
=========================================
Elements defined in MACRO
---------------------------------------------------
seq: <rising edge>
---------------------------------------------------
1: <*>
2: <*>
no unresolved element found
---------------------------------------------------
A (u) behind a macro line signifies an element which could not be assigned. Elements that are not assigned are
either not included in the console configuration or the element was spelt incorrectly.
2.
To view other functions which can be executed from the Telnet session, type macro –h and press Enter:
-d <macro_number> - print the macro number only
-d <all>
- print all macros
-u
- print unresolved only
-e
- erase macro definitions
POWER CORE User Manual
1
|
seq: <falling edge>
|
2: <Master_B_active >
Version: V6.0.0/5
335/459

Advertisement

Table of Contents
loading

Table of Contents