13.5.2 Configuring the Rotary Controls
These parameters configure the rotary 'VCA' controls on the Central Module:
Control n
Name
Default Gain (dB)
Gain Step Width
Set Default Gain
Gain Sync Input
Balance Enable
Balance Sync Input
13.5.3 Additional Module Settings
These are configured in a similar manner to the
13.5.4 Central Modules (monitor mode)
For the each additional Central Module running in monitor mode, parameters are configured in the same way as
for the
Central
Module.
208/459
Enter a reference name for the control on the Central Module.
Enter the name which will appear on the OLED display beside the control. You can enter up
to 6 characters.
Enter a default value in dB. Note that -60dB corresponds to - infinity.
This gain is applied after a cold start and whenever the Set Default Gain control signal (see
below) is active.
Select an option from the drop-down menu. This sets the gain to change in steps of 1dB,
2dB, 3dB or 5dB.
Assign a control signal to activate the Default Gain value. For example, you could assign the
warm start control signal if you wish the level to be reset after a restart.
Assign the output of another
example, to have the headphone level follow the studio monitor level or vice versa.
Tick this box to enable balance control. When enabled, operators can push down and turn
the control to adjust balance.
Assign the output of another
For example, to have the headphone balance follow the studio monitor or vice versa.
Module Parameters
Version: V6.0.0/5
13. Control Surface Configuration
Level
Control. You can use this parameter to link controls. For
Balance
control. You can use this parameter to link controls.
on a Fader Module.