as an authentication key.
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 authentication-key ?
<WORD>
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 authentication-key
aaaaaaaa
WEC8500/configure/router/ospf 2#
Dead-interval configuration
The default value of dead-interval is 4 times of hello-interval. Because the default hello-
interval is configured to 10 sec., the dead-interval will be 40 seconds if the hello-interval is
not configured. In addition, operator can change it to a value between 1 second and 65535
seconds.
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 dead-interval ?
1 - 65535
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 dead-interval 50
WEC8500/configure/router/ospf 2#
Hello-interval configuration
The default hello-interval is 10 seconds. In addition, operator can change it to a value
between 1 second and 65535 seconds.
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 hello-interval ?
1 - 65535
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 hello-interval 50
WEC8500/configure/router/ospf 2#
Message-digest-key configuration
The message-digest-key configures a key ID between 1 and 255. After key ID
configuration, configure the authentication key by using the md5 algorithm. Operator can
enter maximum 16 characters.
When you enter an authentication key, the message-digest-key configuration is
completed.
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 message-digest-key ?
1 - 255
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 message-digest-key 2 ?
md5
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 message-digest-key 2
md5 ?
<WORD>
WEC8500/configure/router/ospf 2# area 2 virtual-link 10.10.10.1 message-digest-key 2 md5
b
WEC8500/configure/router/ospf 2#
Retransmit-interval configuration
The default retransmit-interval is 5 seconds. In addition, operator can change it to a value
between 1 second and 65535 seconds.
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
Authentication key (8 chars)
Seconds
Seconds
Key ID
Use MD5 algorithm
Authentication key (16 chars)