WEC8500/configure/rrm/80211a/chdc# statsCollectEnable
Success: DBI set for DPC 11A Stats collect Enable : 1
5
WEC8500/configure/rrm/80211a/chdc# statsWarningEnable
Success: DBI set for DPC 11A Stats Warning Enable : 1
6
WEC8500/configure/rrm/80211a/chdc# statsActionEnable
Success: DBI set for DPC 11A Stats Action Enable : 1
7
WEC8500/configure/rrm/80211a/chdc# min-failed-client-count 70
CHDC 802.11a : Set Minimum Failed Client Count Success
8
WEC8500/configure/rrm/80211a/chdc# percent-failed-client-count 20
Success: CHDC 802.11a : Set Percentage of Failed Client Count Success
9
WEC8500/configure/rrm/80211a/chdc# rssi-threshold data -75
Success: CHDC 802.11a : Set RSSI THRESHOLD(-75)
WEC8500/configure/rrm/80211a/chdc# rssi-threshold voice -75
Success: CHDC 802.11a : Set RSSI THRESHOLD(-75)
10
WEC8500/configure/rrm/80211a/chdc# statsCollectInterval 60
This Value: 60 is already set
11
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
RRM and CHDC are enabled.
If a coverage hole is estimated from the statistics for the pre-alarm
function, a warning can be transmitted. After entering into the chdc
configuration mode, complete configuration (statsWarningEnable). To
disable the configuration, enter the 'no' parameter.
If a coverage hole is estimated from the statistics for the pre-alarm
function, CHDC can be executed. After entering into the chdc
configuration mode, complete configuration (statsActionEnable). To
disable the configuration, enter the 'no' parameter.
Configure the minimum value of statistics Failed Client Count for the pre-
alarm function.
It can be 1~75.
Configure the percentage of statistics Failed Client Count for the pre-
alarm function.
It can be 10~35.
Configure the threshold of RSSI that will be added to the statistics Failed
Client Count for the pre-alarm function. Configure it for Voice Frame and
Data Frame. It can be -90 to -20 (dB).
Configure a value that requests an interval to an AP to collect statistics
for the pre-alarm function. The default is 120 seconds and it can be
30~3600 seconds.
Configure the minimum value of the idle time-out count of statistics for
the pre-alarm function. This parameter can have a value ranging from 0