Figure 65. Time Profile Configuration Window (1); Figure 66. Time Profile Configuration Window (2) - Samsung WEC8500 Operation Manual

Access point controller
Hide thumbs Also See for WEC8500:
Table of Contents

Advertisement

APC# configure terminal
APC/configure# fqm-mode
2
3
Configuration using Web UI
In the menu bar of <WEC Main window>, select <Configuration> and then select the
<Security>  <Access Control Lists>  <Time Profile> menu in the sub-menus.
The configured time profile list is displayed on the window. When you click the <Add> or
<Delete> button, you can add or delete a time profile.
Figure 65.
Time Profile Configuration Window (1)
Select an item in the list and perform a detailed configuration.
Figure 66.
Time Profile Configuration Window (2)
After finishing configuration in the window, click the <Apply> button to apply it to the
system.
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
Configure a time profile. The 'no' parameter is used to delete a time
profile.
o time-profile
day-start
day-stop
time-start
time-stop
monthdays
weekdays (any|VARIABLE))
o no time-profile [PROFILE_NAME]
Parameter
PROFILE_NAME
To check the configured time profile, use the 'show running-config
network' command.
(any|YY[-MM[-DD[THH[:MM[:SS]]]]])
(any|YY[-MM[-DD[THH[:MM[:SS]]]]])
Description
Name of a time profile to configure
[PROFILE_NAME]
(any|HH:MM[:SS])
(any|HH:[MM:SS])
(any|[0-31])
102