Samsung WEC8500 Operation Manual page 496

Access point controller
Hide thumbs Also See for WEC8500:
Table of Contents

Advertisement

[Retrieving APC information registered on Sync List]
You can check the APC information registered on the Sync List using the 'show
configuration-sync list-apc' command.
WEC8500# show configuration-sync list-apc
======================================================================
INDEX
APC-NAME
======================================================================
1
APC_01
2
APC_02
======================================================================
[Sync Role Configuration]
Available synchronization roles include Master, Slave, and Standalone. Only one Master
is allowed within a synchronization domain. When there is an existing Master and a new
APC's role is changed to Master, the new APC's synchronization role changes to Master,
and the existing master APC's role automatically changes to Slave.
WEC8500/configure# configuration-sync activeactive-role ?
master
slave
standalone
[Sync Role Retrieval]
Synchronization roles can be checked using 'show configuration-sync conf' on the CLI.
The MyAPC information is shown first, followed by the PeerAPC information.
WEC8500# show configuration-sync conf
Current APC ID
Role
PeerAPC id
Role
Link Status
Master ID
Master change time : Wed May 27 19:47:32 2015
Sync status
Configuration using Web UI
[Adding APC to APC List]
Add APCs to synchronize to the APC list by referring to 'APC List Management'.
[Synchronization Configuration]
In the menu bar of <WEC Main window>, select <Configuration> and then select the
<Configuration Synchronization>  <General> menu in the sub-menus.
The top APC of Sync. Members means your APC. If click APC NAME of your APC, you
can change your Role at the Role config menu.
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
Parameter
INDEX
IP-VER
IP-ADDRESS
IP-V6
2001:172:20:4::182
IP-V6
2001:172:20:4::183
Master
Slave
Standalone
: 1
: master
: 2
: slave
: connected
: 1
: Normal
Description
Index on the Sync List (range: 1-2)
CONNECT-STATUS
CONNECTED[1]
CONNECTED[1]
477

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wec8050

Table of Contents