Samsung WEC8500 Operation Manual page 173

Access point controller
Hide thumbs Also See for WEC8500:
Table of Contents

Advertisement

Configuring SSL (Smart Service Link) of AP Group with CLI
1
WEC8500# configure terminal
WEC8500/configure#
2
3
4
WEC8500# configure terminal
WEC8500/configure# ap-group default
GroupName : default
WEC8500/configure/ap-group default# sta-ssl
WEC8500/configure/ap-group default/sta-ssl# ?
decision-delta
enable
number-of-channel
number-of-proreq
time scanning
scan-time-channel
scan-time-interleave
scan-time-service
scan-trigger-level
target-ap
<cr>
WEC8500/configure/ap-group default/sta-ssl# enable ?
<cr>
WEC8500/configure/ap-group default/sta-ssl# decision-delta ?
1 - 100
WEC8500/configure/ap-group default/sta-ssl# number-of-channel ?
1 - 20
WEC8500/configure/ap-group default/sta-ssl# number-of-proreq ?
1 - 10
WEC8500/configure/ap-group default/sta-ssl# scan-time-channel ?
0 - 100
WEC8500/configure/ap-group default/sta-ssl# scan-time-interleave ?
1000 - 10000
WEC8500/configure/ap-group default/sta-ssl# scan-time-service ?
1 - 1000
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
Go to the configure mode of the CLI.
Create an AP group or enter the AP group configuration mode.
ap-group[AP_GROUP_NAME]
Enter the profile configuration mode for the AP group.
profile
Configure the SSL function for the AP group.
o enable: Enables/disables the SSL function.
o target-ap: This option is used for selecting APs that will have the
changes applied to the group settings. If 'all' is selected, changes are
applied to all APs and the configuration priority of the APs also
changes to group. If 'keep-ap-config' is selected, only the APs whose
config priority is set to group have the SSL value of the group applied
to them.
Set delta value for handover decision
sta-ssl enable
Set the number of channel required during one time scanning
Set the number of probe request required during one
Set time required for one channel scanning
Set interval time required for new scanning start
Set time required for STA service during STA's scanning
Set a trigger level for STA's scanning start
Set config target ap
Enter the value [dBm]
Enter the number
Enter the number
Enter the time [ms]
Enter the time [ms]
Enter the time [ms]
154

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wec8050