F(f1, f1j, f2)→fx3 series replacement guidance
Hide thumbs Also See for FX Series:
Table of Contents

Advertisement

2. OVERVIEW OF PROGRAM CONVERSION USING FX-20P-E
(3) On the "2.HPP↔PC" window, use the [↑] and [↓] keys to select
"HPP←PC" and press the [GO] key. The window shown on the right is
displayed.
CAUTION
The display and creation of programs using FX-20P-E + FX-20P-E-
FKIT are done offline.
Always read the program from the programmable controller first before converting it.
When converting F programs to FX programs, they are not written to F
mable controllers.
(4) Press the [GO] key to read (transfer) programs. A message stating "EXECUTING" is dis-
played.
Once the program has been read, the message changes to "COMPLETED".
An error message is displayed if the program cannot be read successfully.
For information on how to resolve error messages, refer to the FX-20P-E-FKIT Operation Man-
ual.
2.3.3

Converting programs

This section describes the operation to convert programs from the target programmable controller
that was read in FX-20P-E (F
For information on program conversion rules, refer to Chapter 3.
■ Important points
To convert programs used with a capacity of 2000 steps ("F2/2K" selected as the model) in an F
programmable controller, read the programs from the F
following programs first.
For information on how to change programs, refer to the FX-20P-E-FKIT Operation Manual.
Program modification details
Add (write) an END instruction to the end of the program (last step of 1999).
(1) Press the [OTHER] key to display the "MODE MENU" window.
(2) On the "MODE MENU" window, use the [↑]
and [↓] keys to select "3.F→FX CONVERT"
and press the [GO] key. The "OLD SYSTEM"
window shown on the right is displayed
according to the model selected during sys-
tem startup.
18
, F
, or F
) to programs for FX3 series programmable controllers.
1
1J
2
1
programmable controller and change the
2
When F1/F2 is selected
for PC type
*OLD SYSTEM*
1. F1-60M
2. F1-40M
3. F1-30M
4. F1-20M
5. F1-12M
6. F2-60M
7. F2-40M
8. F2-20M
9. DEFAULT
2. HPP
PC
HPP PC
OK
[GO]
NO
[CLEAR]
, F
, and F
program-
1J
2
2
MODE MENU
1. PROGRAM CHECK
2. HPP
PC
3. F FX CONVERT
4. BUZZER LEVEL
When F2/2K is selected
for PC type
*OLD SYSTEM*
1. F2-60M
2. F2-40M
3. DEFAULT