Fcdomain - Cisco MDS 9000 series Command Reference Manual

Hide thumbs Also See for MDS 9000 series:
Table of Contents

Advertisement

fcdomain

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
fcdomain
To configure the Fibre Channel domain feature, use the fcdomain command. To disable the FC domain,
use the no form of the command.
Syntax Description
allowed domain
vsan vsan-id
auto-reconfigure
contiguous-allocation
domain id
preferred
static
fabric-name name
fcid
database
persistent
optimize fast-restart
priority value
restart
disruptive
Cisco MDS 9000 Family Command Reference
8-16
fcdomain {allowed domain vsan vsan-id |
auto-reconfigure vsan vsan-id |
contiguous-allocation vsan vsan-id |
domain id {preferred | static} vsan vsan-id |
fabric-name name vsan vsan-id |
fcid {database | persistent vsan vsan-id} |
optimize fast-restart vsan vsan-id |
priority value vsan vsan-id |
restart [disruptive] vsan vsan-id |
vsan vsan-id}
no fcdomain {allowed domain vsan vsan-id |
auto-reconfigure vsan vsan-id |
contiguous-allocation vsan vsan-id |
domain id {preferred | static} vsan vsan-id |
fabric-name name vsan vsan-id |
fcid persistent vsan vsan-id |
optimize fast-restart vsan vsan-id |
priority value vsan vsan-id |
vsan vsan-id}
Configures the allowed domain ID list ranging from 1 to 239.
Specifies a VSAN ID. The range is 1 to 4093.
Configures autoreconfigure.
Configures contiguous allocation.
Configures the domain ID and its type. The range is 0 to 239.
Configures the domain ID as preferred. By default, the local switch accepts
the domain ID assigned by the principal switch and the assigned domain ID
becomes the runtime domain ID.
Configures the domain ID as static. The assigned domain ID is discarded, all
local interfaces are isolated, and the local switch assigns itself the configured
domain ID, which becomes the runtime domain ID.
Specifies the fabric name. The name format is hh:hh:hh:hh:hh:hh:hh:hh.
Configures FC domain persistent FC IDs.
Enters persistent FC IDs submode.
Enables or disables FC domain persistent FC IDs.
Enables a domain manager fast restart on a specified VSAN.
Specifies the FC domain priority. The range is 1 to 254.
Starts a disruptive or nondisruptive reconfiguration.
Forces the disruptive fabric reconfiguration.
Chapter 8
F Commands
OL-8413-07, Cisco MDS SAN-OS Release 3.x

Advertisement