Configuring Fibre Channel Domain Parameters
SUMMARY STEPS
1. configure terminal
2. fcdomain priority number vsan vsan-id
3. no fcdomain priority number vsan vsan-id
DETAILED STEPS
Command or Action
Step 1
configure terminal
Example:
switch# configure terminal
switch(config)#
Step 2
fcdomain priority number vsan vsan-id
Example:
switch(config)# fcdomain priority 12 vsan 1
Step 3
no fcdomain priority number vsan vsan-id
Example:
switch(config)# no fcdomain priority 12 vsan
1

About fcdomain Initiation

By default, the fcdomain feature is enabled on each switch. If you disable the fcdomain feature in a switch,
that switch can no longer participate with other switches in the fabric. The fcdomain configuration is applied
to runtime through a disruptive restart.

Disabling or Reenabling fcdomains

To disable or reenable fcdomains in a single VSAN or a range of VSANs, perform this task:
SUMMARY STEPS
1. switch# configure terminal
2. switch(config)# no fcdomain vsan vsan-id - vsan-id
3. switch(config)# fcdomain vsan vsan-id
OL-27583-01
Purpose
Enters global configuration mode.
Configures the specified priority for the local switch in the
specified VSAN. The fcdomain priority ranges from 1 to 254.
The VSAN ID ranges from 1 to 4093.
Reverts the priority to the factory default (128) in the specified
VSAN. The fcdomain priority ranges from 1 to 254. The VSAN
ID ranges from 1 to 4093.
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)