BATCH Control Center
9.8 Batch control
Command in the context menu Meaning
Resume step
Complete step
Stop step
Abort step
Reset step
Set/remove breakpoint
SFC visualization > Open
overview
SFC visualization > Open
pane
Comment batch element ...
418
Reaction
Execution of the con‐
The "Resume step" command resumes steps
trol recipe is resumed
on hold (RUP, SUB, ROP). If recipe phases
at the held step.
have also been stopped then these phases
return to the status "Running".
Note:
Steps in the error state can be reactivated
with "Resume step".
Execution of the step
This command terminates the recipe phase
is completed.
of a step (RUP, SUB, ROP, RPH) that is non-
self-terminating (requirement: Ready status).
The processing of the
You will find further information in the section
control recipe is stop‐
"Stop step (Page 1117)".
ped at this step.
The processing of the
You will find further information in the section
control recipe is abor‐
"Abort step (Page 1118)".
ted at this step
Execution of the step
Following an abort, the unit or the equipment
is reset
modules of the step are normally still alloca‐
ted. "Reset step" cancels the allocation IDs of
all the recipe phases in the step (RUP, SUB,
ROP, RPH).
The breakpoint is dis‐
You can find additional information in the sec‐
played as a red dot
tion "Setting breakpoints (Page 425)".
next to the control rec‐
ipe element.
This function opens
Requirements:
the overview window
● The corresponding recipe phase must be
of the SFC visualiza‐
tion. Double-click in
the window to display
● The PCS 7 OS Client add-on must also be
the content.
This function opens a
Requirements:
detail window of the
● The corresponding recipe phase must be
SFC visualization.
● The PCS 7 OS Client add-on must also be
Add comments for the
-
individual batch ele‐
ments. This can be
done before, during
and after the runtime
of a batch.
configured as an SFC type in PCS 7
Engineering.
installed on the PC in addition to an
installation of the BATCH Client.
configured as an SFC type in PCS 7
Engineering.
installed on the PC in addition to an
installation of the BATCH Client.
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA