Siemens SIMATIC BATCH Operating Manual page 308

Process control system pcs 7
Table of Contents

Advertisement

BATCH Control Center
9.5 Recipes
Follow the steps outlined below:
1. Select the master recipe in the "Master recipes" or in one of its subfolders in the BatchCC.
2. Select the menu command Edit > Properties.
Result: The dialog box "Properties of <recipe name>" is displayed.
3. Change to the tabs for input materials, output materials, or parameters.
4. Create the reference to a parameter in the formula category in the "Source" column.
– Left-click: The list box contains all the formula parameters of the same data type and
– Right-click: Another dialog box opens. When creating new parameters, you can use this
5. Confirm the references with "OK".
The header parameter is connected to the parameter of the external formula using the
parameter of the formula category provided this master recipe was already assigned to a
formula (see also section Specifying the Properties of the Formula (Page 306)). The values
of the formula are used in the parameters of the master recipe.
Display of parameter interconnection
The interconnection is displayed in the properties dialog of the formula with a connection icon
in the "Usage" column:
308
same physical unit for selection. It may be necessary to assign the unit first in the "Phys.
unit" column. "<E>" is shown under Value indicating external (see figure).
to check whether a parameter of the same name at a different level will be overwritten
and if this is the case, you can see the level at which the parameter exists.
: interconnected
: not interconnected (or no longer interconnected)