All components listed in the dialog must meet the following criteria to allow the BATCH clients
to start:
● Redundancy status: Master or Standalone
● Starting the BATCH Launch Coordinator: Running
Ignore status of BATCH server applications
With this option, the BATCH client starts immediately (only possible at the start of the
application) without waiting for all required server applications to become available. The status
of the "SIMATIC BATCH applications" is ignored.
This means that it is possible to work with the application without the BATCH control server,
Batch data management (Batch CDV) etc. being operational. In some circumstances you can
only work offline.
Note
The "Ignore status of BATCH server applications" function cannot be used with redundant
BATCH servers.
Work without redundant partner
If you select a row with the description "User action necessary", the "Work without redundant
partner" button is activated. With this button, the computer can be instructed to work without
its redundant partner and (in the case of redundancy with data replication) without its partner
database.
Note
If a computer is used without its redundant partner, none of the redundancy characteristics of
the overall system are available any longer.
Close application
Closes the BatchCC or the BATCH Recipe Editor.
14.1.11.7

""Folder" dialog box (Properties)

In this dialog box, you can enter the name and a description of the new folder.