Process Tag Selection - Siemens SIMATIC BATCH Operating Manual

Process control system pcs 7
Table of Contents

Advertisement

Context help references
14.1 Dialogs
14.1.12.31
"Process tag" selection

Process tag selection

In the "Process cell data" list you have selected the "process tag" object.
Run time name in the dialog header
Display of the run time name.
Process cell data
For navigation in the process cell data
Properties
Name of the object selected in the process cell tree.
Description
Runtime name
CFC chart
Open button
Not possible in the multi‐
project.
Assigned process tag
type
Type button
Bloc
Button
Compile
This button only exists for
a project and not for a
multiproject.
906
Description: You can display or enter the description of the interface block
in this text box. You can enter a descriptive text in the object properties in
the SIMATIC Manager.
Corresponds to the WinCC variable name plus the OS name as prefix.
CFC chart name in which the block is located.
Click on the "Open" button to open the appropriate CFC chart and select
the block.
Typing definition for process cell neutral recipe creation.
Clicking this button jumps to the corresponding process tag type. With the
Back button of the process tag type, you return to this location.
All batch instance blocks of the CFC chart of the selected object are read
in. This also implicitly involves a check for consistency with the batch types
and conformity to ISA-88.