Advertisement

Error: Free hard disk memory space
If the available hard disk memory space of the partition on which the SIMATIC BATCH data
is located drops below the value (in %) entered of the total size of the partition, an error
message is output as system message in BatchCC in addition to an error message on the
PCS 7 OS. In addition, you experience the following functional limitations:
● No new batches and no new job folders can be created.
● New batches cannot be started manually or automatically.
● No new recipes, libraries, formulas, formula categories, materials or qualities can be
created.
Note
Even if the set limits are undershot, active batches will continue to run and can still be operated.
However, deterministic and stable system behavior can no longer be guaranteed in such cases
until the hard disk memory space has been increased accordingly.
Warning: Free hard disk memory space
If the free hard disk memory space of the partition on which the SIMATIC BATCH data is
located drops below the value (in %) entered of the total size of the partition, a warning is
output as system message in BatchCC in addition to a warning on the PCS 7 OS.
Monitoring time for batch and step commands
When a batch or step command does not result in the desired target status within the selected
time in seconds, the command is treated as not appropriately completed and a warning
message is output. The warning message shown as dialog is acknowledged with the "OK"
button. The further recipe execution is not affected by the warning message. The warning
message is only output for your information. The warning message is also displayed in the
"Extended batch information" dialog in BatchCC.
The default value is 30 seconds. Numbers between 10 and 10000 seconds are permitted.
You can find additional information in the section "Extended batch information (Page 264)".
"OK" button
Exits the dialog and saves your settings.
"Standard" button
When you click this button, all project settings you have changed in this folder are reset to the
default settings.
"Apply" button
Saves your settings without closing the dialog.
SIMATIC BATCH V8.2