Create Batches" Dialog Box - Siemens SIMATIC BATCH Operating Manual

Process control system pcs 7
Table of Contents

Advertisement

Additional information
"Assignment" tab in the "Updating the process cell" dialog (Page 800)
14.1.9.6

"Create batches" dialog box

Introduction
In this dialog, you can automate the creation of batches. After entering a total quantity, the
number of batches is calculated automatically with the appropriate quantities.
Master recipe
Displays the master recipe selected in the previous dialog.
Formula
Displays the formula selected in the previous dialog.
Minimum/maximum quantity of a batch
Displays the minimum and maximum quantity for the formula/master recipe selected in the
previous dialog "Select formula".
A comma is converted to a period in numbers for their display and their continued use within
SIMATIC BATCH. This means that a period is used as the decimal separator. A thousand
separator is not used or displayed.
Requested quantity
Here, you enter the required quantity of the product.
Name of the batches
Here you enter the name required for the batches.
Start mode of batches
Select the Start mode for all new batches (operator, immediate, time-driven).
Planned start time of the batches
Select the planned start time of all new batches.
Strategy, Maximum utilization
Select this option if you want each batch to produce the maximum possible quantity. The last
batch produces the remainder.
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA
Context help references
14.1 Dialogs
805