EMIOSCNT
0x000008
0x000001
Output pin
A1 value
A2 value
B1 value
EDPOL = 0
Prescaler ratio = 1
Figure 22-34. OPWFMB mode from 100% to 0% duty cycle
A 0% duty cycle signal is generated if A1 = 0x0 as shown in
match from cycle 8 occurs at the same time as the A1 = 0x0 match from cycle 9. Please, refer to
Figure 22-31
for a description of the A1 and B1 match generation. In this case A1 match has precedence
over B1 match and the output signal transitions to EDPOL.
22.5.1.1.9
Output pulse width modulation buffered (OPWMB) mode
OPWMB mode (MODE[0:6] = 11000b0) is used to generate pulses with programmable leading and
trailing edge placement. An external counter driven in MCB Up mode must be selected from one of the
counter buses. A1 register value defines the first edge and B1 the second edge. The output signal polarity
is defined by the EDPOL bit. If EDPOL is zero, a negative edge occurs when A1 matches the selected
counter bus and a positive edge occurs when B1 matches the selected counter bus.
The A1 and B1 registers are double buffered and updated from A2 and B2, respectively, at the cycle
boundary. The load operation is similar to the OPWFMB mode. Please refer to
information about A1 and B1 registers update.
FLAG can be generated at B1 matches, when MODE[5] is cleared, or in both A1 and B1 matches, when
MODE[5] is set. If subsequent matches occur on comparators A and B, the PWM pulses continue to be
generated, regardless of the state of the FLAG bit.
FORCMA and FORCMB bits allow the software to force the output flip-flop to the level corresponding
to a match on A1 or B1 respectively. FLAG bit is not set by the FORCMA and FORCMB operations.
At OPWMB mode entry the output flip-flop is set to the value of the EDPOL bit in the EMIOS_CCR[n].
Some rules applicable to the OPWMB mode are listed as follows:
B1 matches have precedence over A1 matches if they occur at the same time within the same
counter cycle
A1 = 0 match from cycle n has precedence over B1 match from cycle n-1
A1 matches are masked out if they occur after B1 match within the same cycle
Any value written to A2 or B2 on cycle n is loaded to A1 and B1 registers at the following cycle
boundary (assuming OU[n] bit of EMIOS_OUDR is not asserted). Thus the new values will be
used for A1 and B1 matches in cycle n+1.
Freescale Semiconductor
cycle 1
cycle 2
cycle 3
cycle 4
100%
0x000008 0x000007 0x000006 0x000005 0x000004 0x000003 0x000002 0x000001 0x000000
0x000007 0x000006 0x000005 0x000004 0x000003 0x000002 0x000001 0x000000
0x000008
MPC5644A Microcontroller Reference Manual, Rev. 6
Configurable Enhanced Modular IO Subsystem (eMIOS200)
cycle 5
cycle 6
cycle 7
cycle 8
Figure 22-34
cycle 9. In this case B1 = 0x8
Figure 22-32
cycle 9
0%
for more
679

Advertisement

Table of Contents
loading

Table of Contents