STEP
6
INSPECT GENERATOR CONTROL TERMINAL
FOR SHORT TO POWER
• Measure resistance between generator
terminal D (part-side) and body ground.
• Is voltage B+?
7
VERIFY TROUBLESHOOTING OF DTC P2504
COMPLETED
• Make sure to reconnect all connectors.
• Clear DTC from PCM memory using WDS or
equivalent.
• Perform KOER self-test.
(See
F–66 KOEO/KOER
• Is same DTC present?
8
VERIFY AFTER REPAIR PROCEDURE
• Perform "After Repair Procedure".
(See
F–66 AFTER REPAIR
• Is there any DTC present?
End Of Sie
F–180
ON-BOARD DIAGNOSTIC
INSPECTION
SELF-TEST.)
PROCEDURE.)
Yes Repair or replace generator, then go to Step 7.
No
Go to next step.
Yes Replace PCM, then go to next step.
(See
F–43 PCM
REMOVAL/INSTALLATION.)
No
Go to next step.
Yes Go to applicable DTC troubleshooting.
(See
F–67 DTC
TABLE.)
No
Troubleshooting completed.
ACTION