GENERATOR REMOVAL/INSTALLATION

Warning
• When the battery cables are connected, touching the vehicle body with generator terminal B will
generate sparks. This can cause personal injury, fire, and damage to the electrical components.
Always disconnect the battery negative cables before performing the following operation.
Caution
• The generator can be damaged by the heat from the exhaust manifold. Make sure the generator
duct and the generator heat insulator are installed securely.
1. Disconnect the negative battery cable.
2. Remove the under cover.
3. Disconnect the joint shaft from the drive shaft (RH). (R.H.D.) (See
INSTALLATION.)
4. Remove the drive belt. (See
5. Remove in the order indicated in the table.
6. Install in the reverse order of removal.
1
Generator duct
2
B terminal cable
3
Generator connector
Generator Removal Note
1. Remove the generator from above. (L.H.D.)
2. Remove the generator from below. (R.H.D.)
End Of Sie
G–6
CHARGING SYSTEM
B–3 DRIVE BELT
REPLACEMENT.)
M–17 DRIVE SHAFT REMOVAL/
4
Generator heat insulator
5
Generator
(See
G–6 Generator Removal
A6E471018300W01