Avaya DEFINITY Server CSI Maintenance Manual page 1441

Table of Contents

Advertisement

PE-BCHL (PRI Endpoint Port)
Table 378. PRI Endpoint Port Service States — Continued
Possible
Problem
Source
Processor
Interface
Link busied
out by
system
technician?
Check link
status.
[MIPS only].
Signaling
link has
been down
for over 90
seconds?
Repeated
failure of
far-end to
respond to
messaging?
Far-end port
busied out
(OOS/FE).
Far-end port
being tested
(MTCE/FE).
555-233-119
X
X
Warn
Alarm
X
Warn
Alarm
X
X
Warn
Warn
Alarm
Alarm
Possible Recovery
Route
Release link by the
release link lnk-no.
See ISDN-SGRP,
ISDN-LNK, PKT-INT
and/or SYS-LINK and
follow repair
procedures.
Is far-end terminal
adapter currently
restarting?
Periodically
Maintenance will try to
resend messages. To
speed process, run
system
technician-demanded
test test port
PCSSpp (Test #256).
Check status of
far-end terminal
adapter.
Continued on next page
Issue 5 October 2002
1441