Alm_Clr Specifications; Connect Specifications - YASKAWA SGM Series User Manual

Hide thumbs Also See for SGM Series:
Table of Contents

Advertisement

6.4.6 ALM_CLR Specifications

ALM CLR
1
2
3
4
5
ALM CLR MODE
6
7
8
9
10
11
12
13
14
15
16
WDT
ALM_CLR_MODE
0
1
Note It takes approx. 100 ms to clear. Do not clear alarm/warning status history oc-
currences while the motor is driving.

6.4.7 CONNECT Specifications

1
CONNECT
2
3
4
5
VER
6
COM_MODE
7
COM_TIME
8
9
10
11
12
13
14
15
16
WDT
The ALM_CLR_MODE at the fifth byte of ALM_CLR (clear
alarm/warning status) is the field used to select objects that will be
cleared, and it can be specified for each product.
The following are ALM_CLR_MODE specifications for the
SGDB-jjjN.
Clear current alarm/warning status
Clear alarm/warning status history
CONNECT (establish connection) is limited in the SGDB-jjjN
to the following items.
S COM_MODE
D7
D6
D5
DTMOD:
Data transfer method
10: Multiple is not supported.
S COM_TIME
Use 2≦COM_TIME≦32.
6 -11
6.4 Special Descriptions
Description
D4
D3
D2
DTMOD
SYNCMOD EXMOD
6
D1
D0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdb seriesSgmgSgmsSgmdSgmp

Table of Contents