Kw To 3.0 Kw Servodrives - YASKAWA SGM Series User Manual

Hide thumbs Also See for SGM Series:
Table of Contents

Advertisement

Configuration and Connections

4.1.2 2.0 kW to 3.0 kW Servodrives

4.1.2 2.0 kW to 3.0 kW Servodrives
Three-phase 200 to 230 VAC
(50/60 Hz)
Line filter
4
+ 10
–15 %,
Voltage
detection
isolator
Power
Optional circuit
Power
Supply
Supply
board (unmounted)
OFF
ON
Surge
suppressor
Open circuit with
Servo alarm
(Analog monitor output)
Base driver and overcurrent
protection isolator
Relay
Voltage
detection
drive
isolator
DC/DC
conversion
PWM control, etc.
(
Voltage
regulation
Position and speed
(
(Station address selection)
Analog voltage
conversion
(For test)
4 -4
Gate drive
isolator
Current
detec-
tion
ASIC
)
4CN
CPU
1CN
calculation etc.
)
* 2.0 kW with-
out FAN2
Servomotor
Encoder
MECHATROLINK
communication
For I/O signals