User Constants
7.1.7 Memory Switches
7
J Cn-0014 Bit 9: Brake Operation
D Selects the SERVOPACK user constant or the BRK_ON/BRK_OFF command to operate the
brake reference.
D The brake reference is operated by the SERVOPACK user constant when Cn-0014 bit 9 is
set to 1.
J Cn-0014 Bit 10: P-OT Signal Logic
D The P-OT signal logic is reversed when Cn−0014 bit 10 is set to 1. Forward drive is prohib-
ited when the P-OT signal is turned OFF (Signal is CLOSED).
J Cn-0014 Bit 11: N-OT Signal Logic
D The N-OT signal logic is reversed when Cn−0014 bit 11 is set to 1. Reverse drive is prohib-
ited when the N-OT signal is turned OFF (Signal is CLOSED).
J Cn-0014 Bit 12: DEC Signal Logic
D The DEC signal logic is reversed when Cn−0014 bit 12 is set to 1.
D The motor moves at zero point return approach speed 1 when the DEC signal is turned OFF
(Signal is OPEN).
D The motor searches for the origin pulse at zero point return approach speed 2 when the DEC
signal is turned ON (Signal is CLOSED).