User Constants
7.1.4 Sequence-related Constants
7.1.4 Sequence-related Constants
7
D Specifying a value other than 0 applies a secondary lag filter.
D Allowable setting range: 0 to 25000 [µs]
The following sequence-related user constants are available.
J Cn-0012: Time Delay from Brake Reference to Servo OFF
D Sets the time delay from the brake reference output to Servo OFF when a Servomotor with
a brake is used.
D Allowable setting range: 0 to 50 [¢ 10 ms]
Servo ON
Brake Release
Drive ON
J Cn-0015: Brake Timing During Motor Running (Motor Speed for
Brake ON Reference)
D Sets the motor speed at which a brake reference is turned ON during servo OFF.
D If the motor speed is faster than this setting speed, the brake is releasing.
D Allowable setting range: 0 to maximum motor speed [r/min]
J Cn-0016: Time Delay from Servo OFF to Forced Brake ON During
Motor Running
D Sets the time delay from Servo OFF until the brake ON.
D The mechanical brake is not immediately applied when the motor speed is faster than the
speed that was set to Cn-0015 after Servo is turned OFF. When the setting time has passed,
the brake hold regardless of the motor speed.
D Allowable setting range: 10 to 100 [¢ 10 ms]
Servo OFF
Brake Hold
Drive OFF
Cn-0012