6. Enter the desired value in the Packet Filter String field.
7. Click Start in the Pcap Feature field to start capturing signal traffic.
8. Reproduce the issue to get stack traces.
9. Click Stop in the Pcap Feature field to stop capturing.
10. Click Export to open the file download window, and then save the file to your local system.

Ethernet Software Capturing Configuration

You can choose to capture the packets using the Ethernet software in two ways:
Receiving data packets from the hub: Connect the Internet port of the IP phone and the PC to the same hub, and
l
then use Sniffer, Ethereal or Wireshark software to capture the signal traffic.
Receiving data packets from PC port: Connect the Internet port of the IP phone to the Internet and the PC port of
l
the IP phone to a PC. Before capturing the signal traffic, make sure the IP phone can span data packets received
from the Internet port to the PC port. It is not applicable to CP920 phones.
Topic

Span to PC Port Configuration

Span to PC Port Configuration
The following table lists the parameter you can use to configure span to PC port.
Parameter static.network.span_to_pc_port
It enables or disables the IP phone to span data packets received from the WAN port to the PC port.
Description
Note: It works only if "static.network.pc_port.enable" is set to 1 (Auto Negotiation). It is not applicable to
CP920 IP phones.
0-Disabled
Permitted
Values
1-Enabled, all data packets from Internet port can be received by PC port.
Default
0
Web UI
Network->Advanced->Span to PC->Span to PC Port
[1]
If you change this parameter, the IP phone will reboot to make the change take effect.