Yealink SIP-T2 Series Administrator's Manual page 375

Hide thumbs Also See for SIP-T2 Series:
Table of Contents

Advertisement

odically throughout a call.
Permitted
0-Disabled
1-Enabled
Values
Default
0
Web UI
Settings->Voice Monitoring->VQ RTCP-XR Interval Report
Parameter phone_setting.vq_rtcpxr_interval_period
It configures the interval (in seconds) for the IP phone to send an interval quality report to the central
report collector periodically throughout a call.
Description
Note: It works only if "phone_setting.vq_rtcpxr.interval_report.enable" is set to 1 (Enabled).
Permitted
Integer from 5 to 20
Values
Default
20
Web UI
Settings->Voice Monitoring->Period for Interval Report
Parameter phone_setting.vq_rtcpxr_moslq_threshold_warning <y0000000000xx>.cfg
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold value
of MOS-LQ causes the phone to send a warning alert quality report to the central report collector.
For example, a configured value of 35 corresponds to the MOS score 3.5. When the MOS-LQ value com-
Description
puted by the phone is less than or equal to 3.5, the phone will send a warning alert quality report to the
central report collector. When the MOS-LQ value computed by the phone is greater than 3.5, the phone
will not send a warning alert quality report to the central report collector.
If it is set to blank, warning alerts are not generated due to MOS-LQ.
Permitted
15 to 40
Values
Default
Blank
Web UI
Settings->Voice Monitoring->Warning threshold for Moslq
Parameter phone_setting.vq_rtcpxr_moslq_threshold_critical
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold value
of MOS-LQ causes the phone to send a critical alert quality report to the central report collector.
For example, a configured value of 28 corresponds to the MOS score 2.8. When the MOS-LQ value com-
Description
puted by the phone is less than or equal to 2.8, the phone will send a critical alert quality report to the
central report collector. When the MOS-LQ value computed by the phone is greater than 2.8, the phone
will not send a critical alert quality report to the central report collector.
If it is set to blank, critical alerts are not generated due to MOS-LQ.
Permitted
15 to 40
Values
Default
Blank
Web UI
Settings->Voice Monitoring->Critical threshold for Moslq
Parameter phone_setting.vq_rtcpxr_delay_threshold_warning
It configures the threshold value of one-way delay (in milliseconds) that causes the phone to send a warn-
Description
ing alert quality report to the central report collector.
<y0000000000xx>.cfg
<y0000000000xx>.cfg
<y0000000000xx>.cfg
Audio Features
369

Advertisement

Table of Contents
loading

Table of Contents