Calibration Menu - Agilent Technologies ENA Series User Manual

Rf network analyzer
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Softkey Functions

Calibration Menu

Calibration Menu
Key Operation
Displays softkeys for setting and executing calibrations.
Enables or disables error correction.
Correction
Displays softkeys for selecting calibration options.
Calibrate
Displays softkeys for selecting options for response calibration using the OPEN standard.
Response (Open)
Displays softkeys for selecting a test port.
Select Port
Selects test port 1.
1
Selects test port 2.
2
*1
Selects test port 3.
3
*2
Selects test port 4.
4
Returns to the softkey display screen one level higher.
Cancel
Executes a response calibration using the OPEN standard on the
Open
test port selected in the
effective for eliminating response tracking errors.
Executes an isolation calibration using the LOAD standard on the
Load (Optional)
test port selected in the
effective for eliminating directivity errors.
Terminates a calibration process and calculates the calibration
Done
coefficients.
Displays softkeys for canceling a calibration.
Cancel
Cancels the calibration in progress.
OK
Returns to the softkey display screen one level higher.
Cancel
Returns to the softkey display screen one level higher.
Return
Displays softkeys for selecting options for a response calibration using the SHORT standard.
Response (Short)
Displays softkeys for selecting a test port.
Select Port
Selects test port 1.
1
Selects test port 2.
2
*1
Selects test port 3.
3
Selects test port 4.
*2
4
Returns to the softkey display screen one level higher.
Cancel
Executes a SHORT calibration on the test port selected in the
Short
Select Port
reflection tracking errors.
Executes an isolation calibration using the LOAD standard on the
Load (Optional)
test port selected in the
effective for eliminating directivity errors.
Terminates a calibration process and calculates the calibration
Done
coefficients.
Displays softkeys for canceling a calibration.
Cancel
Cancels the calibration in progress.
OK
Returns to the softkey display screen one level higher.
Cancel
Returns to the softkey display screen one level higher.
Return
414
Function
menu. This calibration is
Select Port
menu. This calibration is
Select Port
menu. This calibration is effective for eliminating
menu. This calibration is
Select Port
SCPI Command
:SENS{1-9}:CORR:STAT
:SENS{1-9}:CORR:COLL:METH:OPEN 1
:SENS{1-9}:CORR:COLL:METH:OPEN 2
:SENS{1-9}:CORR:COLL:METH:OPEN 3
:SENS{1-9}:CORR:COLL:METH:OPEN 4
:SENS{1-9}:CORR:COLL:OPEN
:SENS{1-9}:CORR:COLL:LOAD
:SENS{1-9}:CORR:COLL:SAVE
None
:SENS{1-9}:CORR:COLL:METH:SHOR 1
:SENS{1-9}:CORR:COLL:METH:SHOR 2
:SENS{1-9}:CORR:COLL:METH:SHOR 3
:SENS{1-9}:CORR:COLL:METH:SHOR 4
:SENS{1-9}:CORR:COLL:SHOR
:SENS{1-9}:CORR:COLL:LOAD
:SENS{1-9}:CORR:COLL:SAVE
None
Appendix D