Measurement capabilities

Number of measurement channels
Number of display windows
Number of traces
Measurement choices
Measurement parameter conversion
Data formats
Data markers
Marker functions
Marker-to functions
Time domain functions
Transformation
Gated functions
Chapter 15
Up to 9 independent measurement channels. A measurement channel is
coupled to stimulus response settings including frequency, IF
bandwidth, power level, and number of points.
Each measurement channel has a display window. Up to 9 display
windows (channels) can be displayed.
Up to 9 data traces and 9 memory traces per channel. 81 total traces and
81 memory traces can be displayed.
Opt. 213/214: S
Opt. 313/314: S
S-parameters, Balance parameters, CMRR
Opt. 413/414: S
S
, S
, S
, S
14
24
34
CMRR
Available to convert S-parameters into reflection impedance,
transmission impedance, reflection admittance, transmission
admittance, and 1/S.
Log magnitude, linear magnitude, phase, extended phase, positive
phase, group delay, SWR, real, imaginary, Smith chart, polar.
10 independent markers per trace. Reference marker available for delta
marker operation. Smith chart format includes 5 marker formats: linear
magnitude/phase, log magnitude/phase, real/imaginary, R + jX, and G +
jB. Polar chart format includes 3 marker formats: linear
magnitude/phase, log magnitude/phase, and real/imaginary.
Max value, Min value, peak, peak left, peak right, target, target left,
Marker search
target right, bandwidth parameters with user-defined bandwidth values.
Set start, stop, center to active marker stimulus value; set reference to
active marker response value.
Tracking
Performs marker search continuously or on demand.
Selectable transformation type from bandpass, lowpass inpulse, lowpass
step.
Selectable window from maximum, nomal and minimum.
Selectable gated filter type from bandpass, notch.
Selectable gate shape from maximum, nomal and wide.
Specifications and Supplemental Information
Measurement capabilities
, S
, S
, S
11
21
12
22
, S
, S
, S
, S
, S
, S
, S
11
21
31
12
22
32
13
, S
, S
, S
, S
, S
, S
, S
11
21
31
41
12
22
32
, Mixed mode S-parameters, Balance parameters,
44
, S
, Mixed-mode
23
33
, S
, S
, S
, S
,
42
13
23
33
43
349

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5070E5071a

Table of Contents