Measurement Menu (Balanced Measurement, Se-Se-Bal) - Agilent Technologies ENA Series User Manual

Rf network analyzer
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Measurement Menu (Balanced Measurement, SE-SE-Bal)

Key Operation
Displays softkeys for setting measurement parameters (only for models with Option 413 or 414). To display
these softkeys, the balanced/unbalanced conversion topology must be set to unbalanced-unbalanced-balanced
), the balanced/unbalanced conversion function must be on (
SE-SE-Bal
function must be on (
Selects parameter S
Sss11
input to (unbalanced) port 1 on the DUT is reflected as an
unbalanced signal.
Selects parameter S
Sss21
input to (unbalanced) port 1 on the DUT is transmitted to
(unbalanced) port 2 on the DUT as an unbalanced signal.
Selects parameter S
Sss12
input to (unbalanced) port 2 on the DUT is transmitted to
(unbalanced) port 1 on the DUT as an unbalanced signal.
Selects parameter S
Sss22
input to (unbalanced) port 2 on the DUT is reflected as an
unbalanced signal.
Selects parameter S
Sds31
signal input to (unbalanced) port 1 on the DUT is transmitted to
(balanced) port 3 on the DUT as a differential signal.
Selects parameter S
Sds32
signal input to (unbalanced) port 2 on the DUT is transmitted to
(balanced) port 3 on the DUT as a differential signal.
Selects parameter S
Ssd13
input to (balanced) port 3 on the DUT is transmitted to
(unbalanced) port 1 on the DUT as an unbalanced signal.
Selects parameter S
Ssd23
input to (balanced) port 3 on the DUT is transmitted to
(unbalanced) port 2 on the DUT as an unbalanced signal.
Selects parameter S
Scs31
signal input to (unbalanced) port 1 on the DUT is transmitted to
(balanced) port 3 on the DUT as a common mode signal.
Selects parameter S
Scs32
signal input to (unbalanced) port 2 on the DUT is transmitted to
(balanced) port 3 on the DUT as a common mode signal.
Selects parameter S
Ssc13
signal input to (balanced) port 3 on the DUT is transmitted to
(unbalanced) port 1 on the DUT as an unbalanced signal.
Selects parameter S
Ssc23
signal input to (balanced) port 3 on the DUT is transmitted to
(unbalanced) port 2 on the DUT as an unbalanced signal.
Selects parameter S
Sdd33
input to (balanced) port 3 on the DUT is reflected as a differential
signal.
Selects parameter S
Scd33
input to (balanced) port 3 on the DUT is reflected as a common
mode signal.
Selects parameter S
Sdc33
signal input to (balanced) port 3 on the DUT is reflected as a
differential signal.
Appendix D
Measurement Menu (Balanced Measurement, SE-SE-Bal)
Function
) in the "Analysis Menu" on page 405.
Fixture Simulator ON
. S
defines the way an unbalanced signal
ss11
ss11
. S
defines the way an unbalanced signal
ss21
ss21
. S
defines the way an unbalanced signal
ss12
ss12
. S
defines the way an unbalanced signal
ss22
ss22
. S
defines the way an unbalanced
ds31
ds31
. S
defines the way an unbalanced
ds32
ds32
. S
defines the way a differential signal
sd13
sd13
. S
defines the way a differential signal
sd23
sd23
. S
defines the way an unbalanced
cs31
cs31
. S
defines the way an unbalanced
cs32
cs32
. S
defines the way a common mode
sc13
sc13
. S
defines the way a common mode
sc23
sc23
. S
defines the way a differential signal
dd33
dd33
. S
defines the way a differential signal
cd33
cd33
. S
defines the way a common mode
dc33
dc33
Softkey Functions
SCPI Command
), and the fixture simulator
BalUn ON
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSS11
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSS21
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSS12
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSS22
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SDS31
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SDS32
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSD13
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSD23
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SCS31
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SCS32
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSC13
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SSC23
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SDD33
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SCD33
:CALC{1-9}:FSIM:BAL:PAR{1-9}:SSB SDC33
439

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5070E5071a

Table of Contents