Agilent Technologies ENA Series User Manual page 418

Rf network analyzer
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Softkey Functions
Analysis Menu
Key Operation
(Continued)
Fixture Simulator
Displays softkeys for setting up the differential impedance conversion function. When the reference impedance of
*1
Diff ZConversion
two unbalanced ports is expressed as Z
of the converted balanced port to 2Z
conversion is a function that further converts 2Z
Enables or disables the differential impedance conversion function.
Diff
ZConversion
Sets the differential reference impedance of balanced port 1.
*2
Port1 (bal)
Sets the differential reference impedance of balanced port 2.
Port2 (bal)
*2
Sets the differential reference impedance of balanced port 3.
Port3 (bal)
Returns to the softkey display screen one level higher.
Return
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the common impedance conversion function. When the reference impedance of
Cmn
*1
two unbalanced ports is expressed as Z
ZConversion
of the converted balanced port to 2Z
conversion is a function that further converts Z
Enables or disables the common impedance conversion function.
Cmn
ZConversion
Sets the common reference impedance of balanced port 1.
*2
Port1 (bal)
Sets the common reference impedance of balanced port 2.
Port2 (bal)
*2
Sets the common reference impedance of balanced port 3.
Port3 (bal)
Returns to the softkey display screen one level higher.
Return
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the gating function of the time domain function.
Gating
Enables or disables the gating function.
Gating
Sets the start value of the gate.
Start
Sets the stop value of the gate.
Stop
Sets the center value of the gate.
Center
Sets the span value of the gate.
Span
Sets a type of the gate (bandpass/notch).
Type
Displays softkeys for selecting a shape of the gate.
Shape
Selects the maximum shape.
Maximum
Selects the wide shape.
Wide
Selects the normal shape.
Normal
Selects the minimum shape.
Minimum
Returns to the softkey display screen one level higher.
Cancel
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the transform function of the time domain function.
Transform
Enables or disables the transform function.
Transform
Sets the start value.
Start
Sets the stop value.
Stop
410
Function
, an automatic conversion sets the differential mode reference impedance
0
and the common mode reference impedance to Z
0
into another reference impedance.
0
, an automatic conversion sets the differential mode reference impedance
0
and the common mode reference impedance to Z
0
/2 into another reference impedance.
0
SCPI Command
/2. Differential impedance
0
:CALC{1-9}:FSIM:BAL:DZC:STAT
:CALC{1-9}:FSIM:BAL:DZC:
BPOR1:Z0
:CALC{1-9}:FSIM:BAL:DZC:
BPOR{1-2}:Z0
:CALC{1-9}:FSIM:BAL:DZC:
BPOR1:Z0
/2. Common impedance
0
:CALC{1-9}:FSIM:BAL:CZC:STAT
:CALC{1-9}:FSIM:BAL:CZC:
BPOR1:Z0
:CALC{1-9}:FSIM:BAL:CZC:
BPOR{1-2}:Z0
:CALC{1-9}:FSIM:BAL:CZC:
BPOR1:Z0
:CALC{1-9}:FILT:TIME:STAT
:CALC{1-9}:FILT:TIME:STAR
:CALC{1-9}:FILT:TIME:STOP
:CALC{1-9}:FILT:TIME:CENT
:CALC{1-9}:FILT:TIME:SPAN
:CALC{1-9}:FILT:TIME:SPAN
:CALC{1-9}:FILT:TIME:SHAP MAX
:CALC{1-9}:FILT:TIME:SHAP WIDE
:CALC{1-9}:FILT:TIME:SHAP NORM
:CALC{1-9}:FILT:TIME:SHAP MIN
:CALC{1-9}:TRAN:TIME:STAT
:CALC{1-9}:TRAN:TIME:STAR
:CALC{1-9}:TRAN:TIME:STOP
Appendix D